Product Description
Tramex Concrete Determinator Inspector Kit - CDIK
The complete kit for instant and precise testing of both Surface and In-Body concrete Moisture Content in floors and slabs using a unified gravimetric-based testing method. The Tramex CMEX5 digital moisture meter allows for non-destructive quantitative testing of concrete and comparative testing per ASTM F2659. The reusable Concrete Moisture Determinator Probe used with the CMEX5 allows for in-depth moisture content probe testing within the concrete, down to an extendable depth of up to 4 in. (100mm), Diameter 3/4 in. (19mm). The CMEX5 also incorporates reusable plug-in Hygro-i2 RH probes for in-situ testing of concrete. An infrared surface thermometer gives surface temperature and dew point conditions when used in conjunction with the CMEX5 hygrometer. The Concrete Determinator Inspector Kit comes in a protective heavy-duty carrying case with die-cut foam lining. The Tramex Meters App allows you to GeoTag test results, create, save and share reports and charts, as well as see your meter screen on your phone when using the CMEX5 extension handle.
- Instant and accurate
- Designed to work in the same drill-hole made for the F2170 test.
- Eliminate confusion between in-situ Relative Humidity tests and surface Moisture Content tests.
- Determine if moisture is coming from below or above the concrete slab surface.
- Determine the type and extent of mitigation if needed.
- Reusable, Extendable, and requires no plastic hole liners.
- The Concrete Determinator can be used in conjunction with Tramex Concrete Moisture Encounters CME5, CMEX5, (CME4 and CMEX2)
The Concrete Moisture Probe when used with Tramex CME instruments operates on the principle that the electrical impedance of a material varies with its moisture content. The CME instrument is pressed onto the CMP cradle which is pressed onto the material surface with the pins fully compressed and the probe inserted into the pre-drilled 3/4 in. (19mm) hole to measure the moisture content. The electrical impedance is measured by creating a low frequency alternating electric field between the electrodes and the probe, to a depth of up to 4 in. (10cm). This field penetrates the material under test. The very small alternating current flowing through the field is inversely proportional to the impedance of the material. The instrument detects this current, determines its amplitude and thus derives the moisture value.
Operating Procedure:
The Determinator cradle should be flat on the slab surface and the Tramex Concrete Moisture Meter placed and firmly pressed onto the cradle with the pins fully compressed. The probe reads from the bottom, within the body of the slab, up to the surface.
Size: 17.1” x 14.2” x 5.5” (43.5cm x 36cm x 14cm)
Weight: 7.9 lbs (3.6 kg)
Construction: ABS Body
Concrete Moisture Encounter X5 - CMEX5 - Measuring Range:
Depth of penetration in concrete: approx. ¾" (20mm)
Moisture content for Concrete: 0 → 6.9 %
Comparative for Gypsum floor screed: 0 → 12
CM Equiv Anhydrite/Concrete: 0→2.7 / 0→4.3
Reference scale: 0 → 100
Relative Humidity: 0 → 99%
(with optional Hygro-i2 ® probe): Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F
Moisture content for wood (with optional wood pin probes): 5 → 30 %
Concrete moisture probe 'The Determinator' - Measuring Range:
Moisture Content for Concrete with Tramex CMEX5 and CMEX2: 0 - 6.9%
Moisture Content for Concrete with Tramex CME5 and CME4: 0 - 6%
Depth of Penetration: 1 1/4” probe depth for concrete between 2” to 4”
- 2 1/4” probe depth for concrete between 4” to 6”
- 3 1/4” probe depth for concrete between 6” to 9”
- 4 1/4” probe depth for concrete between 9” to 11”
The IRT2 is a handheld, dual laser, non-contact Infrared Thermometer with 12:1 distance to spot ratio and audible and visible high/low set point alarms. It is used to measure and display surface temperatures within the range of -50°C to 650°C (-58ºF to 1202ºF) and has an accuracy of approximately 1 to 1.5%. The IRT2 has a fast response time (0.15 sec) and is powered with a 9V battery and complies with Class II UK/EU laser safety standard EN60285.
Tramex Concrete Determinator Inspection Kit Data
Tramex CMEX5 Quick Start Guide
Tramex Concrete Determinator Quick Start Guide
Tramex Concrete Determinator User Manual