Product Description
Testo Fast IR Printer 0554 0549
Testo Fast IR Printer 0554 0549- Record up to 999 hours of measurement values via the optional "EasyKool" software.
- Refrigerants can be updated by customer, if needed.
- Direct onsite printout is possible with optional testo fast printer.
- Extensive accessories are available for use with the 570.
*The following 40 refrigerants come pre-loaded in the Testo 557.
R12 R404A R416A R434A R123 R406A R417A R437A R1234YF R407A R420A R438A R134A R407C R421A R502 R22 R408A R421B R503 R290 R409A R422A R507 R401A R410A R422B R600 R401B R411A R422D R600A R402A R413A R424A R744 (CO2) R402B R414B R427A R718 (water)
Built in Vacuum Gauge
*The following 40 refrigerants come pre-loaded in the Testo 557.
R12 | R404A | R416A | R434A |
R123 | R406A | R417A | R437A |
R1234YF | R407A | R420A | R438A |
R134A | R407C | R421A | R502 |
R22 | R408A | R421B | R503 |
R290 | R409A | R422A | R507 |
R401A | R410A | R422B | R600 |
R401B | R411A | R422D | R600A |
R402A | R413A | R424A | R744 (CO2) |
R402B | R414B | R427A | R718 (water) |
Number of refrigerant profiles: | 40 |
Pressure measurement range: | -14.7 to 580 psi |
Vacuum indication: | 0 inHg to 29.92 inHg |
Units of measure: | °F, °C, psi, inHg, bar, kPa, MPa |
Resolution pressure: | 0.1 psi |
Accuracy pressure sensor: | ± 0.75 % fs (+1 Digit) |
Pressure media: | HCFC, HFC, N, H2O |
Temperature: | 2x NTC ports |
Measuring range temperature: | -58...248 °F |
Temperature resolution: | 0.1°F |
Temperature accuracy: | ± 1.8 °F (+1 Digit) |
Valve block configuration: | 2-way valve block with 3 hose connections |
Display illumination: | Yes |
Power supply: | 4xAA |
Battery Life: | 150 hrs. (without illumination) |
Ambient operating temperature: | 14 to 122°F |
Measurement cycle time: | 0.5 seconds |
Maximum working pressure: | 870 psi |
Product Videos