Product Description
Sensorcon Legacy Inspector Industrial Pro Carbon Monoxide Detector and CO Meter - INS-CO-03

The Sensorcon Legacy Inspector Industrial Pro (INS-CO-03) is the original green-face Pro model. It has adjustable alarm points (low 5-100 ppm, high 40-500 ppm), a TWA exposure reading, a vibrating alarm, and intrinsic-safety certification to UL Std 913 and CSA Std C22.2 No. 157. The Legacy series carries a one-year Sensorcon warranty.
Reasons to Buy the Legacy Industrial Pro
- Adjustable alarms: Low 5-100 ppm, high 40-500 ppm; ships at 35 and 200 ppm.
- TWA: Highest 8-hour average CO exposure in the last 24 hours.
- Vibration, buzzer and LEDs on every alarm.
- Intrinsically safe: UL 913 / CSA C22.2 No. 157 (Intertek/ETL control no. 4004813).
- Same feature set and sensor specifications as the Inspector 2 Industrial Pro, with a one-year warranty.
On the Job
Program-specific alarm levels: Set the low and high alarms to the levels your safety plan specifies.
End-of-shift review: Check the TWA screen to see the highest 8-hour average from the last 24 hours alongside the live and MAX readings.
Legacy Industrial Pro or Inspector 2 Industrial Pro?
Same alarms, TWA, vibration and certification. The Inspector 2 Industrial Pro (INS2-CO-03) carries a two-year warranty and is also offered as a kit with hand pump and case.
| Feature | Legacy Inspector INS-CO-01 |
Legacy Industrial INS-CO-02 |
Legacy Industrial Pro INS-CO-03 |
|---|---|---|---|
| Continuous ppm display | Yes | Yes | Yes |
| MAX (peak hold) mode | Yes | Yes | Yes |
| Buzzer + LEDs | Yes | Yes | Yes |
| Vibrates on alarm | — | Yes | Yes |
| Low and high set points | 35 / 200 ppm | 35 / 200 ppm | Adjustable |
| TWA exposure reading | — | — | Yes |
| Intrinsically safe | — | Yes | Yes |
| Coverage | 1 year | 1 year | 1 year |
| Inspector 2 equivalent | INS2-CO-01 | INS2-CO-02 | INS2-CO-03 |
| View model | View | View | View |
Technical Specifications
| Model / type | Sensorcon Legacy Inspector Industrial Pro INS-CO-03 |
|---|---|
| Sensing technology | Electrochemical |
| Measures / displays | Measures 0-500 ppm; display reads to 1,999 ppm |
| Resolution | Whole ppm (1 ppm) |
| Accuracy | ±10%, or ±2 ppm at readings below 20 ppm |
| Speed of response | Initial under 5 seconds; T90 under 20 seconds |
| Alarm points | Adjustable: low 5-100 ppm, high 40-500 ppm (ships at 35 / 200 ppm) |
| Warning signals | Buzzer at 80-85 dB plus four red lights around the display; vibration |
| Adjustable alarms | 5-100 ppm (low), 40-500 ppm (high) |
| TWA exposure screen | Highest 8-hour average in the last 24 hours |
| Hazardous locations | UL Std 913 conformance and CSA Std C22.2 No. 157 certification; Intertek/ETL control no. 4004813 |
| Additional marking | CE |
| Battery | Standard CR123A lithium; around 2 years depending on how often it alarms |
| Temperature limits | -4 to 122°F (-20 to 50°C) |
| Humidity rating | 20-90% RH for continuous use; brief exposure 0-99% RH |
| Enclosure | Resists water and impact |
| Size / weight | 3.2 × 2.2 × 0.86 in, 4 oz |
| Carry options | Steel clip with lanyard loop |
| Service interval | Depends on the frequency of its use, the environment it's used in, and how it's stored when not in use; EOL symbol at 2 years, cleared for 180 days by each successful calibration. See manufacturer recommendations for further details. |
| Warranty term | One-year Sensorcon limited warranty |
| Assembly | USA |
Frequently Asked Questions
What is TWA used for?
Exposure limits are set as averages over a shift. The TWA screen gives you the highest 8-hour average from the last 24 hours to compare against your program's limit.
How do I set the low and high alarms?
Open the advanced menu by holding POWER/MUTE and MAX for 5 seconds, step with POWER/MUTE to Lo Alarm SEt or Hi Alarm SEt, and adjust with MAX.
Is it approved for hazardous locations?
It conforms to UL Std 913 and holds CSA Std C22.2 No. 157 certification (Intertek/ETL control no. 4004813). Check those against your site's hazardous-location rules. Never open it or swap the battery where an explosive atmosphere may be present.
Can I use it at home?
Yes, as a supplemental low-level CO detector. It reads live ppm and alarms at its set points without the time delay listed alarms use. It is not UL 2034 listed, so keep the installed alarms that codes require.
What happens when EOL appears on the screen?
EOL shows after two years of use. It does not mean the sensor has failed. A successful calibration with 50 ppm CO gas removes it for 180 days, and you can keep calibrating while the sensor stays in good condition.
What if the sensor wears out?
Send it to Sensorcon for its $69 out-of-warranty renewal: new sensor, new battery, replacement of damaged parts, full calibration and a renewed warranty. Sensorcon sets no limit on how many times a unit can be renewed.
Manuals, Warranty and Service
- Sensorcon Inspector and Inspector 2 Instruction Manual (PDF)
- Sensorcon Inspector Series Brochure (PDF)
- Sensorcon Warranty, Repairs and Returns
- Sensorcon Calibration Service
Sensorcon · Built to be rebuilt
Own a Professional-Grade CO Monitor for Less Than $50 a Year
Buy it once. Rebuild it for years.
Why throw away a disposable CO detector when you can rebuild it for just $69?
*Example based on the Sensorcon Legacy Inspector (INS-CO-01): $154 + two $69 Sensorcon rebuilds over six years. Prices subject to change.
AV8
Inspector 2
Legacy*